MIL-PRF-1/1383D
TABLE I. Testing and inspection - Continued.
Inspection
Method Notes
Conditions
Acceptance Symbol
Limits
Unit
MIL-STD-
level
1311
12/
Min
Max
Conformance inspection,
part 1 Continued
16/ 19/ Eb = 26 kV dc;
Peak power output (2)
---
0.65
po
180
---
kw
ec2 = 2 kv;
Ec1 = 15/;
rf drive/Ib = 750 mA dc;
Ic1 = 125 mA dc (max);
Ic2 = 175 mA dc (max);
F = 550 ± 25 MHz;
t = 60 minutes
Peak power output (1)
---
15/ 16/ Eb = 23 kV dc;
0.65
po
200
---
kw
19/ ec2 = 1.8 kv;
rf drive/Ib = 750 mA dc;
Ic1 = 125 mA dc (max);
Ic2 = 175 mA dc (max);
F = 215 ± 15 MHz;
t = 60 minutes
µF
Direct-interelectrode
1331
2/
Grid 2 to filament
0.65
Cg2k
0.011
0.018
capacitance
Anode to grid 1
0.65
Cg1p
---
0.10
pF
Conformance inspection,
part 2
18/
Input resonant frequency
---
---
Fi
265
295
MHz
Output resonant
---
18/
---
Fo
245
275
MHz
frequency
Conformance inspection,
part 3
11/ 13/ po = 180 kw (min);
Service-life guarantee
---
---
---
---
---
---
F = 174 to 575 MHz;
t = 1,000 hours
Service-life guarantee
---
end points:
19/
Peak power output (1)
---
---
po
160
---
kw
19/
Peak power output (2)
---
---
po
160
---
kw