MIL-PRF-1/1383D
TABLE I. Testing and inspection.
Inspection
Method Notes
Conditions
Acceptance Symbol
Limits
Unit
MIL-STD-
level
1311
12/
Min
Max
First article inspection
Life test
---
---
---
---
---
---
1/ 11/ po = 180 kw (min);
12/ 13/ F = 215 ± 15 MHz
16/
11/ 16/ F = 215 ± 15 MHz
Life test end point
---
---
po
180
---
kw
Vibration
---
21/ 24/
---
---
---
---
---
Shock
---
22/ 24/
---
---
---
---
---
Vibration and shock test
---
end point:
Peak power output (1)
---
---
po
180
---
kw
Conformance inspection,
part 1
1155
No voltages applied
0.65
APD
---
18
psi
Anode water pressure
14/
differential
Grid 2 water pressure
1155
No voltages applied
0.65
SPD
---
17
psi
14/
differential
Grid 1 water pressure
1155
14/
No voltages applied
0.65
GPD
---
9
psi
differential
Filament section (1) water
1155
14/
No voltages applied
0.65
FPD1
---
17
psi
pressure differential
Filament section (2) water
1155
14/
No voltages applied
0.65
FPD2
---
17
psi
pressure differential
DC cathode water
1155
14/
No voltages applied
0.65
CPD
---
11
psi
pressure differential
Filament current per
1301
---
0.65
If
950
1,050
A
section
ĆIf
Filament current
---
3/
0.65
---
30
A
differential
17/ 20/ Eb = 10 kV dc ± 500 V dc;
µA dc
Total grid current
1266
0.65
Ic
---
-170
Ec2 = 900 V dc;
Ec1/Ib = 1.5 A dc;
t = 5 minutes
See footnotes at end of table.