MIL-PRF-1/1000B
TABLE I. Testing and inspection - Continued.
1/
The type 6164 is an integral cavity broad-band transmit-receive tube designed for use in the M85/1-073-120 waveguide. The
magnitude of the vector difference between tubes of low-level reflection and transmission are not greater than 4 dB SWR and 10°,
respectively, over the range of 8,500 to 9,500 MHz.
2/
Unless otherwise specified, the acceptance level for all tests listed under conformance inspection, part 1, shall be 1.0 in
accordance with MIL-PRF-1, Table III accept on zero (c = 0) sampling plan.
3/
With a metal plate shorting the line, the position of the VSW minimum shall be determined. The metal plate shall be replaced by
the tube under test and the position of the VSW minimum of the flat position of the pulse shall be measured and shall be .032 inch
(0.81 mm) further from the magnetron within the limits specified.
4/
This test shall be conducted in accordance with test procedure for reflection and transmission differences described herein.
5/
Revision letters are not used in this revision to identify changes with respect to the previous issue, due to the extensiveness of the
changes.