MIL-PRF-1/1705C
TABLE I. Testing and inspection - Continued.
MIL-STD-
Limits
1311
Inspection
Method
Test
Conditions
Symbol
Min
Max
Unit
Conformance inspection,
part 2
MP
---
0.2
%
Stability (3)
4315
1
Ef = 7.6 V and 8.4 V;
F = F1, F3, and F5;
ib = 30A 11/
Resettability
4223
2
F = F1, F3, and F4
---
---
5
MHz
Tuning rate
4223
2
ib = 26A 27/
---
IAW
IAW
---
Fig. 2
Fig. 2
---
5
MHz
Frequency pulling figure
4310
2
F = F1, F3, and F4;
ĆF
ib = 26 A
---
0.1
MHz/A
Frequency pushing
4311
2
F = F1, F3, and F4;
ĆF/ĆA
figure
ib = 23 ± 1A
ib = 29 ± 1A 30/
Power output (2)
4250
3, 4
F1 to F5;
Po
200
350
W
ib = 30A 22/
Conformance inspection,
part 3
Time
2,500
---
hrs
Life test
4551
Group S; sequential life
test portion only 29/
Intermittent life
4551
2
Group D 31/ 32/
Life
1,667
---
Cycles
Life test end points:
ib = 22.5 A
Po
120
---
W
4250
2
Power output
RF bandwidth
4308
2
F = F1, F3, and F5
BW
---
2.2/tpc
MHz
Stability
4315
2
F = F1, F2, and F5
MP
---
0.3
%
ib = 30 A
FM
---
0.2
MHz
Frequency modulation
---
2
F = F1, F3, and F5
ib = 26A
Periodic check tests
28/
Temperature coefficient
4027
2
---
0.25
MHz
T(anode) = 0°C to 115°C;
ĆF/ĆT
F = F4 2/ 15/
Variable frequency
1031
2
F = F1, F3, and F5
FM
---
2.0
MHz
vibration (operating)
ib = 23 and 30A 13/ 24/
Shock
1042
G = 15; t = 11 ms 14/ 25/
See footnotes at end of table.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business