MIL-PRF-1/368G
TABLE I. Testing and inspection.
Inspection
Method
Notes
Test
Conditions
Symbol
Limits
Limits
Units
MIL-STD-
Min
Max
1311
Qualification inspection
Degradation due to vibration
4021
---
---
---
---
---
---
Flat leakage power
4452
---
1
pf
---
50
mW
Spike leakage energy
4452
---
1
Ws
---
0.25
erg
Conformance inspection,
part 1
= 1.05 max
Low-level VSWR
4473
---
---
---
---
1.9
F1
---
---
1.4
F2
F3 0.1 percent
---
---
1.4
---
---
1.4
F4
---
---
1.9
F5
0.8
Insertion loss
dB
4416
---
---
---
F = F3; Ii = 0
Li
Ii = 100 A dc
Ignitor interaction
0.2
dB
4421
---
---
---
Li
Ignitor ignition time
5
sec
4401
1
---
---
Ebb = -700 V dc
t
R = 4.0 Meg 1
percent
Ignitor voltage drop
400
V dc
4406
---
200
---
Ebb = -700 V dc
Eid
R = 4.0 Meg 1
percent
Flat leakage power
50
4452
mw
---
---
2
pf
Spike leakage energy
0.25
erg
4452
---
---
2
Ws
Position of short
0.100
4494
Inch
0.070
2
2
Distance
Arc loss
0.80
4488
dB
---
---
1
Loss
Temperature cycling
---
1027
---
---
---
---
---
(nonoperating)
Conformance inspection,
part 2
4101
Dielectric material strain
4
---
---
---
---
---
s
Recovery time
4471
---
2
t
---
10.0
Conformance inspection,
part 3
Life test
---
3
2
Group C;
t
500
---
hrs
Ebb = -700 V dc;
R = 4.0 Meg 1
percent
See footnotes at end of table I.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business