MIL-PRF-1/1339F
TABLE I. Testing and inspection.
Limits
MIL-STD-1311
Inspection
Unit
Conditions
Symbol
Method
Min
Max
Qualification
Vibration
5111
Width
----
1
mm
Pressure (implosion)
1141
----
----
----
----
Cathode illumination
5216
----
----
----
----
Direct-interelectrode capacitance
1331
g1 to all
Cg1
----
5.5
pF
k to all
Ck
----
4.9
pF
D1 to D2
C1D2
----
3.9
pF
D3 to D4
C3D4
----
2.5
pF
D1 to all
CD1
----
7.9
pF
D2 to all
CD2
----
7.4
pF
D3 to all
CD3
5.5
pF
----
D4 to all
CD4
----
4.8
pF
Deflection-factor uniformity
5248
----
----
1
%
Neck and bulb alignment (electrostatic
5101
Dia
----
2.25
in.
types)
Conformance inspection, part 1
Voltage breakdown
5201
----
----
----
----
Voltage breakdown (electrostatic types)
5201
----
----
----
----
Gas "cross" (electrostatic deflection)
5206
Light = 15 fL
----
----
----
----
2
(51.4 cd/m ) 1/
Screen and faceplate blemishes
5106
----
----
----
----
Light output
5221
Eb = 2500 V
----
15
----
fL
ĆEc
Modulation
5223
Light = 15 fL
----
45
V dc
2
(51.4 cd/m )
Spot position (electrostatic deflection)
5231
----
----
16
mm
Spot displacement (leakage)
5231
Displ
----
10
mm
Grid-cutoff voltage
5241
Eco
-34
-56
V dc
Grid No. 1 leakage current
5251
----
----
----
----
Anode No. 2 leakage current
5251
----
----
----
----
Pattern distortion
----
2/
----
----
----
----
Centering of scan
----
Focused trace;
Ec1 at 10 V drive 3/
±2.00
1D2
----
----
in.
±1.25
3D4
----
----
In.
See footnotes at end of table.