MIL-PRF-1/1336G
TABLE I. Testing and inspection.
Inspection
Method
Conditions
Acceptance
Symbol
Limits
Unit
MIL-STD-
Level 13/
Min
Max
1311
Conformance inspection,
part 1
-5.0
0
t = 120;
Ic1
1266
0.65
Total grid current
µA dc
Rk = 825 ohms 6/
Rk = 825 ohms 6/
0.65
Ib
28
37
mA dc
Electrode current (1)
1256
(anode)
1256
Ebb = 4,000 V dc;
0.65
Ib
0
1.0
mA dc
Electrode current (2)
Ecc2 = 800 V dc;
(anode)
Ecc1 = -150 V dc;
Rp = 2 MegΩ 7/
Electrode current
1256
Rk = 825 ohms
0.65
Ic2
---
3.0
mA dc
(screen)
Conformance inspection,
part 2
---
---
---
Ebb = 4,000 V dc;
---
---
1.0
Pulse operation
Ecc2 = 800 V dc;
Ecc1 = -150 V dc;
egy = 155 v 7/ 8/
Grid-pulse operation
1356
Ebb = 420 V dc;
1.0
ib
5.0
---
a
Ecc2 = 800 V dc;
Ecc1 = -150 V dc;
egy = 155 v 8/
(test in accordance with
figure 4)
1.0
ic2
---
4.0
a
Peak screen current
---
Ebb = 420 V dc;
Ecc2 = 800 V dc;
Ecc1 = -150 V dc;
egy = 155 v 8/
(test in accordance with
figure 4)
1.0
ic1
---
2.0
a
Peak grid current (1)
---
Ebb = 420 V dc;
Ecc2 = 800 V dc;
Ecc1 = -150 V dc;
egy = 155 v 8/
(test in accordance with
figure 4)
1.0
ic1
30
---
ma
Peak grid current (2)
---
Ebb = 420 V dc;
Ecc2 = 800 V dc;
Ecc1 = -150 V dc;
egy = 52 v 8/
See footnotes at end of table.