MIL-PRF-1/964E
TABLE I. Testing and inspection
Inspection
Method
Test
Conditions
Symbol
Unit
Limits
MIL-STD-1311
Min
Max
Conformance inspection,
part 1
Ignitor ignition time
4401
1
t
---
1.0
sec
Ignitor voltage drop
4406
2
Eid
200
400
V dc
Insertion loss (1)
4416
---
F = F2
Li
---
1.5
dB
(integral cavity)
ΔLi
Ignitor interaction
4421
2
---
0.2
dB
(insertion loss)
Tuning range
4426
---
F = F1 to F3
---
5
---
turns
Po
Leakage power
4452
5
F = F2, T = 25°C
---
30
mW
Du
Temperature cycling
1027
---
---
---
---
---
(nonoperating)
Conformance inspection,
part 2
High-frequency vibration
1031
---
t = 15 minutes
---
---
---
---
Loaded Q
4461
---
QL
---
350
---
ΔF
Vibration detuning
4016
---
F = F2, t = 12 hours
---
±3
MHz
μA dc
Ignitor oscillation
4411
---
Li
---
60
(obsolescent)
Insertion loss (2)
4416
---
F = F1 and F3
Li
---
1.5
dB
(Integral cavity)
ΔF
Temperature coefficient
4466
---
F = F1 1/
---
-20
MHz
of frequency
μs
Recovery time
4471
4
F = F2
t
---
4.0
2
Pressurizing
4002
---
---
---
---
---
45 lbf/in
See footnotes at end of table.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business