MIL-PRF-1/507H
Dimensions
Inches
Millimeter
Dimensions
LTR
Min
Max
Min
Max
Inches
Millimeter
Conformance inspection, part 1
LTR
Min
Max
Min
Max
F
8.875
225.42
Conformance inspection, part 2
K
3.625
92.08
A
4.281
108.74
L
1.870
1.970
47.50
50.04
B
2.930
3.070
74.42
77.98
Q
6-32 NC -2B
C
.963
24.46
R
.946
.966
24.03
24.54
D
1.625
41.275
S
2.077
2.217
52.76
56.31
E
1.625
41.275
T
.984
1.004
24.99
25.50
J
2.625 NOM
U
2.499
2.639
63.47
67.03
M
2.000
50.80
AC
3.312
84.12
N
.469
.531
11.91
13.49
AD
7.750
8.250
196.85
209.55
V
7.250
184.15
AE
7.250
7.750
184.15
196.85
W
6.500
165.10
Y
.985
1.135
25.02
28.83
Conformance inspection, part 3
Z
3.780
96.01
(Periodic check)
AA
2.345
59.56
H
1.100
27.94
G
5.178
5.322
131.52
135.18
P
1.297
1.327
32.94
33.71
AB
.173
.203
4.39
5.16
X
1.297
1.327
32.94
33.71
FIGURE 1. Outline and dimensions - Continued.
NOTES:
1
Reference plane "A" is defined as a plane passing along the finished surface of the magnet.
2
Reference plane "B" is defined as a plane passing through the centers of the mounting holes, and
perpendicular to reference plane "A".
3
Reference plane "C" is defined as a plane passing through the center of the mounting hole, and mutually
perpendicular to reference planes "A" and "B".
4
W ire: No. 11 AW G, 7x6x30 AW G or equal.
Insulation: white silicone rubber, fiberglass tubing grade 4A1 or equal.
Lugs: Burndy spade lug YAVIO-T21F or equal; one lug painted brown to identify it as common heater-cathode
connection, outer terminal.
5
Tolerance includes angular as well as lateral deviation(s).
6
These dimensions apply to radiator size only.
7
This dimension refers to centerline of tube.
8
Parts on this centerline may vary (displacement) by 0.125 in.
9. Surface of output flange to be parallel to reference plane "B" within 0.020 in.
10
Tube-to-tube variations shall be within the dimensional tolerances, but hole-to-hole variation on any single
tube shall not vary more than .030-in. within the dimensional tolerances.
11
Heater connection.
12
Point at which temperature shall be measured on anode body.
13
Minimum distance from high-voltage to ground should be 1.500-in. through air, at normal atmospheric pressure.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business