MIL-PRF-1/36J
TABLE I. Testing and Inspection - Continued.
Limits
MIL-STD-1311
Requirement or Test
Unit
Symbol
Type
Conditions
Method
Min
Max
Conformance inspection,
part 1 - continued
Ib3 = 200 µA dc
ĆEc
Modulation
5223
P7
55
V dc
Ib3 = 100 µA dc
ĆEc
P12
40
V dc
Spot position (electrostatic
5231
P1, P2,
---
---
15
mm
deflection)
P11,P12
P7
---
---
12
mm
Spot displacement
5231
All
Displ
---
7
mm
(leakage)
Grid-cutoff voltage
5241
P1, P2,
Ecl
-22.5
-67.5
V dc
P11,P12
P7
Ecl
-30
-90
V dc
Grid No. 1 leakage current
5251
All
---
---
---
---
Anode No. 2 leakage
5251
All
---
---
---
---
current
Light output
5221
P1
Eb2 = 1,500 V;
Light
25
---
fL
Eb3 = 3,000 V;
Ib3 = 100 µA dc
P11
Eb2 = 1,500 V;
Light
9
---
fL
Eb3 = 3,000 V;
Ib3 = 100 µA dc
(see note 5)
Conformance inspection,
part 2
Heater current
1301
All
If
540
660
mA
P1, P2, P11 Ib3 = 100 µA dc
µA dc
Electrode current
5201
Ib1
-50
10
(anode No. 1)
Ib3 = 200 µA dc
µA dc
P7
Ib1
-50
10
Ib3 = 5 µA dc
µA dc
P12
Ib1
-50
10
(see note 1)
Base alignment
5101
All
+1D2, pin No. 5
---
---
---
---
(electrostatic types)
Side terminal alignment
5101
All
+1D2
---
---
---
---
(electrostatic types)
µA dc
Electrode current
5201
P1, P2, P11 See note 2
Ib3
150
---
(anode No. 3)
P1, P2,P11 Ib3 = 100 µA dc
µA dc
Electrode current (cathode)
5201
Ik
---
1,000
Ib3 = 200 µA dc
µA dc
P7
Ik
---
1,500
Ib3 = 5 µA dc
µA dc
P12
Ik
---
100
(see note 1)
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business