MIL-PRF-1/267G
TABLE I. Testing and Inspection.
Limits
MIL-STD-1311
Type
Conditions
Symbol
Requirement or test
Unit
Method
Min
Max
Qualification inspection
Base material insulating
1216
Both Zone 5, or higher
---
---
---
---
quality
Pressure (implosion)
1141
Both
---
---
---
---
Barometric pressure,
1002
Both 225 mmHg
---
---
---
---
reduced
Vibration
5111
Both
Width
---
1
mm
Direct-interelectrode
1331
Both g1 to all
Cg1
---
8.7
pF
capacitance
k to all
Ck
---
5.7
pF
D1 to D2
C1D2
---
3.3
pF
D3 to D4
C3D4
---
2.0
pF
D1 to all, except D2
CD1
7;.2
pF
---
D2 to all, except D1
CD2
7.2
pF
---
D3 to all, except D4
CD3
4.8
pF
---
D4 to all, except D3
CD4
---
4.8
pF
Neck and bulb alignment
5101
Both
Dia.
---
1.63
Inch
(electrostatic types)
Cathode illumination
5216
Both
---
---
---
---
Deflection-factor
5248
Both
---
---
2
%
uniformity
Conformance inspection,
part 1
Bulb, screen, and faceplate
5106
Both
---
---
---
---
quality
Voltage breakdown
5201
Both
---
---
---
---
Voltage breakdown,
5201
Both
---
---
---
---
(electrostatic types)
Gas "cross"
5206
P1
Light = 7 fL
---
---
---
---
(see note 1)
Gas "cross"
5206
P2
Light = 2 fL
---
---
---
---
(see note 1)
Light output
5221
P1
See note 1
Light
7
---
fL
Light output
5221
P2
See note 1
Light
2
---
fL
Spot position
5231
Both
---
---
10
mm
(electrostatic deflection)
Spot displacement
5231
Both
Displ
---
7
mm
(leakage)
Grid cutoff voltage
5241
Both
Eco
-45
-75
V dc
Grid No. 1 leakage current
5251
Both
---
---
---
---
Anode No. 2 leakage
5251
Both
---
---
---
---
current
See notes at end of table.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.