MIL-PRF-1/1314D
TABLE I. Testing and inspection - Continued.
Inspection
Method Types
Conditions
Acceptance Symbol
Limits
Unit
level
10/
Min
Max
Conformance inspection,
part 3
8/
Life test
---
---
t
6283 Group D
500
---
hours
F = 1050 ± 50 MHz;
Ef = 2/;
Eb = 5,000 V dc;
Ec2 = 1,000 V dc;
Ec1 = -200 V dc;
pd = 1.5 kw;
tp = 5-15 µs;
Du = 0.01 4/
Life test (2) provisions
---
8500 Group D;
---
---
---
---
---
F = 850 ± 50 MHz 4/;
Po
140
---
W
(useful)
Eb = 1,500 V dc;
Ic2
---
15
mA dc
Ec2 = Adjust;
Ib = 300 mA dc;
Rg = 2,000 ohms;
Ic1 = 20 mA dc;
Ef = 5.5 V;
t = 500 hours
---
po
12.0
---
kw
Life test end points
---
6283 Power output
F = 405-450 MHz;
Ef = 6.3 V;
Eb = 5,000 V dc;
Ec2 = 1,000 V;
Ec1 = -50 V dc;
pd = 2.2 kw;
tp = 15-17 µs;
Du = .005 4/
Life-test (2) end points
---
8500 Power output (1)
---
Po
135
---
W
F = 850 ± 50 MHz 4/;
(useful)
Ic2
---
20
mA dc
Eb = 1,500 V dc;
Ec2 = Adjust;
Ib = 300 mA dc;
Rg = 2,000 ohms;
Ic1 = 20 mA dc
Pulsing emission sinusoid
---
is
40
---
a
3/
See footnotes at top of next page.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business