MIL-PRF-1/1105A
TABLE I. Testing and inspection.
Limits
Inspection
Method
Conditions
Symbol
Min
Max
Unit
Qualification
Dielectric material
4101
---
---
---
---
Degradation due to
4021
G = 10 1/
---
---
---
---
vibration
F = 8,500 MHz ± 0.1%
δ
---
Low level VSWR
4473
1.2
---
F = 8,800 MHz ± 0.1%
δ
---
1.2
---
F = 9,000 MHz ± 0.1%
δ
---
1.2
---
F = 9,300 MHz ± 0.1%
δ
---
1.2
---
F = 9,600 MHz ± 0.1%
δ
---
1.2
---
F = 8,500 MHz ± 0.1%
Insertion loss
4416
---
---
1.0
dB
F = 8,800 MHz ± 0.1%
---
---
0.8
dB
F = 9,000 MHz ± 0.1%
---
---
0.8
dB
F = 9,300 MHz ± 0.1%
---
---
0.8
dB
F = 9,600 MHz ± 0.1%
---
---
1.0
dB
Ii = 100 µA dc on each ignitor
---
---
---
---
F = 8,500 MHz ± 0.1%
Transmitter - receiver
4491
---
15
---
dB
F = 8,800 MHz ± 0.1%
Isolation
---
15
---
dB
F = 9,000 MHz ± 0.1%
---
15
---
dB
F = 9,300 MHz ± 0.1%
---
15
---
dB
F = 9,600 MHz ± 0.1%
---
15
---
dB
Ii = 100 µA dc on each ignitor
---
---
---
---
Ii = 100 µA dc on each ignitor 2/
Ignitor Interaction
4421
---
---
0.1
dB
Ignitor Ignition time
4401
Ebb = -700 V dc; R = 4.0 Meg 3/
t
---
5.0
sec
Ii = 100 µA dc on each ignitor 4/
Ignitor voltage drop
4406
---
-200
-375
V dc
F = 9000 MHz ± 0.5 %;
Flat leakage power
4452
pf
---
20
mw
po = 40 kw ± 10%;
prr = 1,000;
tp1 = 1.0 ± 0.1 µs;
tp2 = 0.5 ± 0.05 µs;
Ii = 100 µA dc on each ignitor
F = 9,000 MHz ± 0.5%;
Spike leakage energy
4452
Ws
---
0.1
erg
po = 40 kw ± 10%;
prr = 1,000;
tp1 = 1.0 ± 0.1 µs;
tp2 = 0.5 ± 0.05 µs;
Ii = 100 µA dc on each ignitor
F = 9,000 MHz ± 0.5%;
Arc loss
4488
---
---
0.8
dB
po = 40 kw ± 10%;
prr = 1,000;
tp = 1.0 ± 0.15 µs
Temperature cycle
1027
cycles
1
---
---
Temperature cycling life
1027
cycles
10
---
---
See footnotes at end of table.