MIL-PRF-1/1100G
TABLE I. Group A inspection.
Mil-Std-1311
Limits
Inspection
Symbol
Unit
Method
Conditions
Min
Max
Conformance
inspection, part 1
Aac
22.0
15.0
If
3241
Heater current
Aac
6.0
2.0
Ires
Eres = 4.5 Vac
3241
Heater current
4000
---
Ebb
Eres = inscribed value
3247
DC anode voltage for
Vdc
-5 percent
conduction
---
---
---
epy = 18.0 kv(min); Eres
3267
Instantaneous
---
= inscribed value +5 percent
starting 1/ 4/
450
---
egy
epy = 27.5 kv; prr = 450;Eres
3246
v
Operation (1) 1/
= inscribed value -5 percent;
t = 30 minutes
450
---
egy
epy = 20 kv; prr = 1,200;
3246
v
Operation (2) 5/ 6/
Eres = 95 percent of
optimum value (2)
5.5
3.0
Eres
Operation (1)
3246
Vac
Operation of optimum
reservoir voltage(1)
(inscribed value)
5.5
3.0
Eres
Operation (2)
3246
Vac
Operation of 6/
optimum reservoir
voltage (2)
ik = 500 a; tp = 5.0 µs
250
---
egk
3251
v
Pulse emission
±10 percent; prr = 60
±10 percent; tr = 0.5 µs
(max); Eres = inscribed value;
specified time interval = 2.5 µs
Conformance
inspection, part 2
V
450
----
egy
Operation (1), except Eres
3246
Operation (3)
= inscribed value +5 percent;
V
tk = 900 sec; t = 1,200 sec
450
----
egy
Operation (2), except Eres
Operation (4)
3246
µs
= 105 percent optimum value(2)
µs
Operation (1); t = 120 sec
1.0
----
tad
Anode delay time
3256
µs
Anode delay time
Ćtad
0.25
----
Anode delay time
3256
drift 7/
Operation (1); except
0.004
----
epy = 15.0 kv
3261
Time jitter 8/
tj
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business