MIL-E-1/1315E
TABLE I. Testing and inspection.
MIL-STD-1311
Limits
Conditions
Symbol
Unit
Requirement or test
Method
Min Max
First Article Test
See Note 21
ΔP=5.0 in. water
ΔT
Forced convection
1143
--
40
°C
See notes 5, 8, 11 and 14
Shock test
1042
Shock=15 g;
--
--
--
--
no voltages;
See notes 1 and 14
Mechanical tuning fatigue
4223
See notes 13 and 14
Cycles
500
--
--
Conformance inspection, part 1
Heater voltage
1261
If=75A
Ef
2.0
3.0
V
Heater-cathode warmup time
4303
If=75A
tk
--
600
sec
See notes 3 and 9
Pulse voltage
4306
F3
epy
50
60
kv
Power output
4250
F1, F2, F3
Po
1250
--
W
Mechanical tuning range
4223
Anode T = 50 to 100°C
See note 20
Upper limit
F
1350
--
MHz
Lower limit
F
--
1250 MHz
Pulse stability
4315
F2; VSWR=1.5/1
MP
--
1
%
See note 19
Conformance inspection, part 2
Low-frequency vibration
1031
No voltage
--
--
--
--
RF bandwidth
4308
F1, F2, F3
BW
--
1.0
MHz
See note 16
Frequency pulling factor
4310
F2; See note 18
F
--
5
MHz
Frequency pushing factor
4311
F2; See note 17
F
--
0.5
MHz
Pulse stability
4315A
F1, F3; See note 19
MP
--
0.5
%
ℓbf/in
2
Pressurizing
4003
--
45
--
Operating torque of force
4223
See notes 11 and 12
Torque
--
70
in-oz
Tuner stop endurance
4223
See note 11
Torque
150
--
in-oz
Conformance inspection, part 3
Life test
Group D; See note 10
t
500
--
hrs
Life test end points:
Power output
4250
F1, F2, F3
Po
1000
--
W
Pulse stability
4315
See note 19
MP
--
1
%
Pulse voltage
4306
F3
epy
45
--
kv
ΔP=5.0 in. water
Δt
Forced convection
1143
--
40
°C
See notes 5, 8, 11 and 14
Shock test
1042
Shock=15g; no voltages;
--
--
--
--
See notes 1 and 14
Mechanical tuning fatigue
4223
See notes 13 and 14
Cycles
500
--
--
See notes at end of table.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business