MIL-PRF-1/846M
TABLE I. Testing and inspection.
Limits
MIL-STD-1311
Inspection
Notes
Test
Conditions
Symbol
Unit
Method
Min Max
Qualification
inspection
Barometric pressure,
4028
---
1
F5; pressure = 380 mmHg
---
---
---
---
reduced
ĆF
0.25 MHz/°
Temperature
4027
Fig 1 (17)
1
F3; Ib = 10 mA dc;
---
T(anode) = 70°C to 100°C;
ĆT
coefficient
and fig 2
C
magnetic field, 4 shunts
Low-temperature
1047
---
3
F5; Ib = 17.5 mA dc;
---
---
---
---
operation
VSWR = 1.5:1
°C
Forced cooling
1143
12/
1
Pi-Po = 150 W;
T
---
TA
TA = 50°C (max)
+50
Pulse voltage
4306
Fig 2
1
F3; magnetic field,
epy
9
11
kv
4 shunts
Vibration, mechanical
1032
13/ 14/
---
No voltages applied
---
---
---
---
Shock, specified pulse
1042
14/
---
Test condition A, except
---
---
---
---
15G;
no voltages applied
TA = -55°C to +125°C
Operating torque or
4223
---
---
---
---
2.0
in.-lb.
force
Direct-interelectrode
4266
---
---
C
4.0
8.0
pF
capacitance
Mechanical tuning
4223
15/
---
---
2,500
---
Cycles
fatigue
Ćepy
Voltage tuning
---
16/
1
0
+1.5
kv
Tuning characteristics
---
11/
1
---
---
---
---
Conformance
4/
---
inspection, part 1
Pressurizing
4003
---
---
40 psia
---
---
---
---
Heater current,
4289
---
---
Ef = 6.3 V;
If
0.90
1.10
A
nonoperating
tk = 120 (max)
Pulse voltage
4306
---
3
F3
epy
13
15
kv
Power output (1)
4250
---
3
Po
44
---
W
Pulse stability (1)
4315
5/
3
Ib = 17.5 mA dc;
MP
---
1.0
%
VSWR = 1.5:1
See footnotes at end of table.