MIL-PRF-1/296E
TABLE I. Testing and inspection.
Inspection
Method
Conditions
Symbols
Limits
Limits
Unit
MIL-STD-1311
Min
Max
Conformance inspection, part 1
Insertion loss
---
At resonant frequencies
Li
4.0
6.0
dB
Loaded Q
---
QL
1,900
2,400
---
T = 40C to 100C
Temperature cycle (1)
---
1Q22Fo
9249.7
9250.3
MHz
1Q23Fo
9279.7
9280.3
MHz
t = 30 minutes
1Q24Fo
9309.7
9310.3
MHz
see note 3
5846Fo
9279.7
9280.3
MHz
6040Fo
9307.7
9308.3
MHz
6041Fo
9311.7
9312.3
MHz
RF glow test
---
---
---
---
---
see note 5
Conformance inspection, part 2
Fo
Vibration
MHz
1031
---
10 G see note 2
.15
Fo
MHz
Shock
1042B
---
50 G, 6 ms
.15
half-sine
T = 40C to 100C
MHz
Temperature cycle (2)
---
9249.7
9250.3
1Q22Fo
MHz
9279.7
9280.3
t = 12 hours
1Q23Fo
MHz
9309.7
9310.3
see note 3
1Q24Fo
MHz
9279.7
9280.3
5846Fo
MHz
9307.7
9308.3
6040Fo
MHz
9311.7
9312.3
6041Fo
Fo
MHz
Temperature compensation (1)
---
---
10.0
Room temperature to
100C, see note 4
F = 9,800 100 MHz
dB
Off resonance insertion loss
---
30
---
Li
dB
30
---
F = 8,850 100 MHz
Li
---
Pressurizing
4003
---
---
---
45 Psi absolute
see note 8
Conformance inspection, part 3
Life test
---
Group B, t = 30 minutes
Cycles
25
---
---
T = 55C to 100C
see note 6
Life test end points
---
See footnotes at end of table I.