MIL-PRF-1/1698D
TABLE I. Testing and inspection.
Method
Requirement or test
Notes
Conditions
Acceptance Symbol
Limits
Unit
MIL-STD-
level 14/
1311
Min
Max
Conformance inspection,
part 1
Npm
10
---
N/t
2/ 3/ 4/ t = 2 minutes
0.65
6201
Background, contamination,
and photosensitivity
V dc
640
---
Es
0.65
6211
Starting voltage
4/
Pulse amplitude = 1 V;
Nps = 200 (max); R2 = 1
MegΩ ± 10%; R1 = C1 =
C2 = 0; C3 = 0.01 µF ±
10%
%/V dc
0.2
---
Ps
0.65
Relative plateau slope
6216
5/
Voltage range = 660 to
760 V dc
V dc
---
780
Ee
0.65
End-of-plateau voltage
6216
5/
Ps = 0.3/V dc
Nps
125
75
N/t
0.65
Response count rate and
6221
5/ 6/ 7/ t = 2 minutes
current (gamma)
Conformance inspection,
part 2
---
Gamma (radiium) rate
Response current
6221
---
Ib
---
10.0
µA dc
= 500 mr/hr;
Ebb = 710 V dc
4/
Ebb = 675 V dc; Nps
Pulse amplitude (1)
6226
---
eo
2.5
---
v
= 200 (max); R1 = 0.9
MegΩ ± 10%; R2 = 0.1
MegΩ ± 10%; C1 = 330
pF ± 10%; C2 = 3,000 pF
± 10%; C3 = 0.01 µF±
10%; multiply oscillo-
scope reading by 10
Pulse amplitude (2)
4/
6226
---
eo
---
65
v
Pulse amplitude (1),
except Ebb = 725 V dc
Conformance inspection,
part 3
---
---
---
---
16/
---
Group A; counting rate
Life test
---
= 1,000 Nps (min);
t = 500 hours
---
---
---
---
---
Life-test end points
---
10/ 16/
---
---
---
---
---
Variable-frequency vibration
1031
8/ 11/
13/ 15/
---
---
---
---
---
Temperature cycling
---
12/ 13/
---
---
---
---
---
8/ 9/ 600 G
Shock
1041
13/ 15/
0.5
---
LIb
---
Ebb = 500 V dc
Leakage current
6205
13/
µA dc
See footnotes at top of next page.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business