TABLE I. Testing and inspection - Continued.
9/
Pressure drop shall be measured across the anode cooler only, with the tube operating. Anode core temperature shall be
measured with the tube operating, with an ambient air temperature of 25°C, with both base and anode cooled by applying an
airflow of 4.8 cfm maximum at sea level. Temperature shall be measured by means of a thermocouple attached to the top of
the anode core, adjacent to the cooler, by any suitable means. Good electrical continuity between the thermocouple and the
metal area in proximity shall be demonstrated before the cooling test is performed.
10/ Eb of 6,300 V dc (maximum) is permissible under zero drive conditions.
11/ Reclaimed materials shall be utilized to the maximum extent possible.
12/ Test to be performed every three months, utilizing an accept on zero sampling plan.
13/ This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III.
5