MIL-PRF-1/1388G
TABLE I. Testing and inspection.
Inspection
Method
Notes
Conditions
Symbol
Limits
Unit
MIL-STD-1311
Min
Max
Conformance inspection,
part 1
6201
N/t
---
20
Npm
2/ 6/ t = 4 minutes (min)
Background, contamination
and photosensitivity
12/ 17/
6211
5/ 12/ Pulse amplitude = 0.50 V;
Es
---
1,250
V dc
Starting voltage
18/ 19/ Nps = 100 (min);
R2 = 1 MegΩ ± 10%;
R1 = C1 = C2 = 0;
C3 = 0.01 µF ± 10%
End-of-plateau voltage
6216
---
Ps = 3%/100 V dc
Ee
1,650
---
V dc
Relative plateau slope
Voltage range = 1,300
6216
15/
Ps
---
3
%/100 V dc
to 1,600 V dc
6201
2/ 6/ t = 4 minutes (min)
N/t
---
20
Npm
Background, contamination
and photosensitivity
12/ 17/
6221
3/ 6/
N/t
3/
---
Npm
Response count rate and
Ebb = 1,400 V dc;
current (beta)
12/
counting time = 2 minutes (min)
---
14/
---
---
---
---
Shelf life
Conformance inspection,
part 2
µA dc
Ebb = 700
6205
---
Lib
---
0.5
Leakage current
Shock
450 G
1041
1/ 11/
---
---
---
---
20/
Response count rate and
6/ 7/ 8/ Ebb = 1,400 V dc;
6221
---
---
---
---
current (hysteresis (1a))
t = 2 minutes (min);
record count rate values
Response count rate and
Ebb = 1,400 V dc;
6221
6/ 8/
---
---
---
---
current (hysteresis (1b))
t = 15 minutes (min)
±20
6221
6/ 8/
N/t
---
%
Response count rate and
Ebb = 1,400 V dc;
current (hysteresis (1c))
t = 2 minutes (min);
from reading taken from count
rate (1a)
Response count rate and
6/ 9/ 12/ Ebb = 1,400 V dc;
6221
N/t
---
110
Npm
current (gamma)
counting time = 2 minutes (min)
See footnotes at end of table.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business