MIL-PRF-1/1159E
TABLE I. Requirements or tests.
Limits
MIL-STD-1311
Requirement or test
Conditions
Symbol
Unit
Method
Min
Max
Conformance
inspection, part I
---
---
---
---
---
Visual and mechanical
inspection criteria
1231
eb = 1,000 v (max)
is
750
---
ma
Peak emission
1256
Eb = 300 V dc
Ib
290
440
mA dc
Anode current
1301
See note 4
If
4.5
5.25
A
Filament current
1353
t = 60 (see notes 5 and 7)
Io
100
---
mA dc
Operation of rectifiers
Conformance
inspection, part 2
---
---
---
---
---
See figure 1
Dimensions
1101
---
---
---
---
20 inch-pound torque
Secureness of base,
base insert, and cap
1031
No voltages
---
---
---
---
High frequency vibration
1041
300 G (see note 6)
---
---
---
---
Shock
---
See note 3
---
---
---
---
Post-shock end point
Conformance
inspection, part 3
---
Group D, operation of
---
---
---
---
Life-test provisions
rectifiers; T = 125°C;
t = 500 hours (see note 2)
---
is
500
---
ma
Life-test end points
Peak emission and failure to
Io
100
---
mA dc
rectify.
Periodic check tests
---
---
---
---
---
Dimensions
See figure 1
1031
---
---
---
---
Vibration fatigue test
Ef = 5.0 V ac
---
---
---
---
---
Post-vibration fatigue
See note 3.
test end point
See notes on next page.