MIL-PRF-1/1071D
TABLE I. Testing and inspection.
Limits
Inspection
Method
Notes
Tes
Conditions
Symbol
Min
Max
Unit
MIL-STD-1311
t
2/
---
First article inspection
(Preproduction)
3/
Loaded Q
---
4461
QL
---
2.5
---
3/
1
VSWR
---
1.15
---
High-level VSWR
4474
4021
---
---
---
---
---
---
Degradation due to
vibration
4/
Conformance inspection,
---
part 1
3/
Tuning susceptance
---
4482
Method A
b
-0.03
+0.03
---
3/
1
t
---
5
sec
Firing time
4486
3/
1
La
---
0.3
dB
Arc loss
4488
Temperature cycling
1027
---
---
1 cycle
---
---
---
---
1027
---
---
Group D; 10 cycles (min)
---
---
---
---
Temperature cycling life
test
Conformance inspection,
part 2
Dielectric material strain
4101
---
---
---
---
---
---
3/
---
g
---
0.03
---
Normalized conductance
4484
---
---
---
---
1031
---
---
F = 50 to 500 Hz;
Variable-frequency
15 G; t = 30 minutes (min)
vibration
---
---
---
---
5/
---
Insertion
---
Conformance inspection,
part 3
6/
Life test
2
Group D
---
t
1,000
---
hours
---
---
Life-test end points:
---
3/
---
Tuning susceptance
4482
Method A
b
-0.05
+0.05
---
3/
Normalized conductance
4484
---
g
---
0.05
---
3/
Arc loss
4488
1
La
---
0.4
dB
See footnotes at top of next page.