MIL-PRF-1/10J
TABLE I. Test conditions.
MIL-
Acceptance
Limits
Unit
STD-
Requirement or test
Conditions
level
Symbol
1311
(see note 11)
Min
Max
Conformance
Method
inspection, part 1
1301
Heater current
0.4
If
160
190
mA
1336
Heater-cathode
See note 2
0.4
Ihk
---
10
µAdc
leakage
Rg/g = 0.5 MegΩ
1266
Total grid current
0.4
Ic
0
-0.4
µAdc
(see notes 2 and 3)
1256
Electrode current (1)
See note 2
0.4
Ib
0.4
1.8
mAdc
(anode)
1256
Electrode current (2)
Ec = -10.5 Vdc
0.4
Ib
---
10
µAdc
Rp = 0.1 MegΩ
(anode)
(see note 2)
1321
AC amplification
Ebb = 100 Vdc;
0.4
Ep
7.5
---
Vac
Ec = 0; Esig = 0.2 V ac;
Rp = 0.5 MegΩ;
Rg = 10 MegΩ
(see note 2)
1201
Short and discontinuity
0.4
---
---
---
---
detection
Conformance
inspection, part 2
MegΩ
1211
Insulation of
See note 2
2.5
R
500
---
electrodes
1256
Electrode current (1)
2.5
Ib
---
0.6
mAdc
(anode) (difference
between sections)
1306
Transconductance (1)
See note 2
2.5
Sm
900
1600
µmhos
ĆSm
1306
Transconductance (2)
Ef = 11.4 V
2.5
---
15
%
(see note 2)
Ef
See footnotes at end of table.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744