MIL-PRF-1/986J
TABLE I. Testing and inspection.
Acceptance
Limits
MIL-STD-
Unit
Notes
Conditions
level
Symbol
Inspection
Min
Max
1311
Method
14/
Conformance inspection,
part 1
Background,
6201
1/
t = 2 minutes
0.65
N/t
---
10
Npm
contamination, and
(min)
photosensitivity
6211
2/
Nps = 20 nominal;
0.65
Es
710
---
V dc
Starting voltage
R1 = C1 = C2 = 0;
R2 = 1 Meg ± 10%;
C3 = 0.01 µF ±
10%
50 r/hr
6221
4/
0.65
N/t
190
230
Nps
Response count rate and
current
6221
5/ 6/
0.65
---
---
---
---
Response count rate (beta)
Conformance inspection,
part 2
Ebb
---
760
V dc
Pulse amplitude
6226
8/
Nps = 20 nominal;
R1 = 0.1 Meg ±
10%; C1 = 0.01
µF± 10%
Conformance inspection,
part 3
Group C;
---
---
---
---
Life test
---
9/, 16/
counting rate =
1,000 ±50 Nps;
Ebb = 680 V dc;
t = 250 hours
---
---
---
---
Life-test end point
---
10/,16/
7/ 11/
---
---
---
---
Variable-frequency
1031
15/
vibration
µA dc
13/
Ebb = 500 V dc;
Lib
---
0.5
Leakage current
6205
relative humidity
90 ± 5 percent
---
12/ 13/
T = +50°C, -20°C
---
---
---
Temperature
---
---
7/ 15/
Shock
1041
Hammer angle =
---
---
---
40°
See footnotes at top of next page.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business