MIL-PRF-1/973E
Dimensions (see note 2)
Ltr
Inches
Millimeters
Min
Max
Min
Max
A
---
3.500
---
88.90
B
.825
.835
20.96
21.21
C
.058
.068
1.47
1.73
D
.151
.161
3.84
4.09
E
1.344
1.468
34.14
37.29
F
.450
.460
11.43
11.68
G
.442
.452
11.23
11.48
H
.558
.568
14.17
14.43
J
.816
.826
20.73
20.98
K
.151
.161
3.84
4.09
L
.296
.306
7.52
7.77
NOTES:
1. Spray with semi-gloss black enamel after pretest.
2. This test shall be performed during the initial production and once each succeeding 12-calendar months in
which there is production. A sampling plan shall be used with a sample of six tubes with an acceptance
number of zero. In the event of failure, the test will be made as a part of conformance inspection, part 2,
with an acceptance level of 6.5 (see 15/). The regular "12-calendar month" sampling plan shall be
reinstated after three consecutive samples have been accepted.
FIGURE 1. Counter tube assembly (type 5980).