MIL-PRF-1/757K
TABLE I. Testing and inspection. Continued
Acceptance
Limits
Symbol
Unit
Method
Requirement or
Conditions
level
MIL-STD-1311
test
8/
Min
Max
Conformance
inspection, part 3
Continued
Intermittent life-
test end points:
(500 hours)
Inoperatives
See note 2
---
---
---
---
---
138
3241
Heater current
164
---
mA
If
-0.8
3201
Grid voltage (1)
-5.0
---
Vdc
Eccl
---
Anode voltage
1261
70
---
Vdc
Ebb
---
Pulse emission
1231
100
---
v
etd
---
Heater-cathode
1336
Ehk=+25 Vdc
20
---
ľAdc
Ihk
leakage
Ehk=-100 Vdc
20
ľAdc
Ihk
Total defectives
---
----
---
---
---
---
Periodic check
tests
Variable-frequency No voltages
1031A
---
---
10.0
---
---
vibration
See note 7
Sweep-frequency
---
1031A
10G; variable
---
6.5
---
---
vibration
frequency
See note 7
Post-sweep-
----
frequency vibration
test end points:
Ihk
ľAdc
Heater-cathode
1336
---
Ehk=+25 Vdc
20
---
Ihk
ľAdc
leakage
Ehk=-100 Vdc
20
Ebb
Vdc
Anode voltage
1261
---
26
---
NOTES:
1.
See "Reduced pressure (altitude) rating" and altitude, maximum peak voltage in the basic document.
2.
This test is to be the first test performed at the conclusion of the holding period.
3.
Grid current or the appearance of ionized gas shall not be considered as indications of air leakage.
4.
Adjust phase of grid voltage to provide start of conduction at the peak of the anode voltage.
5.
Cycling of heater-cathode voltage shall be 30-seconds positive and 30-seconds negative.
6.
Post-shock and sweep-frequency vibration-test end points, as specified herein, shall be the post-
variable-frequency vibration end points.
7.
This test shall be conducted on the initial lot and thereafter on a lot approximately every six months.
When one lot has passed, the 6-month rule shall apply. In the event of a lot failure, the lot shall be
rejected and the succeeding lots subjected to this test until a lot passes
8.
This specification sheet utilizes an accept on zero defect sampling plan consistent with MIL-PRF-1, table III.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.